sitemap
PagesABOUT US BRIDGE CLIENTS CONTACT CORPORATE HERITAGE BUILDINGS HOME HOME INDUSTRIAL ISO Certificate Management OTHERS OUR PRINCIPAL PROJECTS RESIDENTIAL BUILDING SCHOOL and COLLEGE Services sitemap VIDEO VISION PostsInfinity Cars Service Center work started 2022Home
CORPORATE
Infinity Cars Pvt. Ltd Turbhe -2022 Problem: – First to third floor was damage due to fire.Temperature during fire was 600⁰C.Due to high temperature, surface of concrete is highly carbonated.Micro cracks can be observed on...
BRIDGE
Sanfield India Ltd Mumbra Bridge – 2018 Problem: – Crack was observed on the soffit of the bridge slab.As PWD slab need to be strengthen in flexure zone. Solution: – Scheme was prepared and approved...
sitemap
Home
M F Construction Relentless in our pursuit to consistently excel M F Construction (MFC) founded in 2014 It's a proprietorship firm and Mr. Md. Firoz... Read More"Home"

CORPORATE
Infinity Cars Pvt. Ltd
Turbhe -2022


Problem: –
- First to third floor was damage due to fire.
- Temperature during fire was 600⁰C.
- Due to high temperature, surface of concrete is highly carbonated.
- Micro cracks can be observed on the RCC elements.
Solution :-
- The entire exposed concrete surface was chipped and replaced.
- Column was jacketed with additional steel and Micro-concrete.
- Slab was supported with additional structural steel members.
- Entire external plaster was chipped and replaced with new plaster.
Aditya Birla Centre
Worli Mumbai – 2019-20


Problem: –
- Old Structure and having low grade of concrete.
- Need to increase load bearing capacity of the structure.
- Dis-stress signs were observed in the RCC members.
- Corrosion in the RCC member can be observed.
Solution: –
- Core column was jacketed with micro-concrete and additional steel.
- Carbon fiberwraaping was done for additional strengthening.
- Rust remover and Anti-corrosive was done on the rusted RCC member.
- Grouting was done to increase micro structure of the concrete.
Marquardt India Pvt. Ltd
Kandivali, Mumbai – 2021-22

Problem: –
- Old Structure and having low grade of concrete.
- Need to increase load bearing capacity of the structure.
- Dis-stress signs were observed in the RCC members.
Corrosion in the RCC member can be observed.
Solution: –
- Core column was jacketed with micro-concrete and additional steel.
- Carbon fiberwraaping was done for additional strengthening.
- Rust remover and Anti-corrosive was done on the rusted RCC member.
- Grouting was done to increase micro structure of the concrete.
Pidilite Head Office
Old R&D building – Andheri (E)
Problem: –
- Old structure and concrete grade is less than 20MPa.
- High corrosion in the RCC element.
- NDT results shows poor workman ship.
- Need to increase the load bearing capacity.
Solution: –
- Based on the result hybrid solution was proposed.
- Micro-concrete done on the column followed by carbon fiber wrapping.
- All the slab having major distress was supported with structural steel.
- Slab with minor distress was strengthen with CFRP and FRCM.
Home
M F Construction Relentless in our pursuit to consistently excel M F... Read More"Home"

BRIDGE
Sanfield India Ltd
Mumbra Bridge – 2018


Problem: –
- Crack was observed on the soffit of the bridge slab.
- As PWD slab need to be strengthen in flexure zone.
Solution: –
- Scheme was prepared and approved from IIT, powai Mumbai.
- Slab was strengthen with carbon fiber laminate and carbon fiber rod and followed by carbon fiber wrapping.
Home
M F Construction Relentless in our pursuit to consistently excel M F Construction (MFC) founded in 2014 It’s a proprietorship firm and Mr. Md. Firoz …

OTHERS
MARQUARDT
20021-2022


Problem
- Low concrete strength (10 MPa) and inadequate axial load capacity was observed
- Additional strong room load over the columns
- Corrosion damages were observed
- Being a heritage structure, no demolition work was allowed.
Solution:
- RCC members were treated for corrosion damages and polymer modified mortar was used to rebuild sections.
- Axial load carrying capacity of circular columns was increased using multiple layers of GFRP.